Fix thermal-pressure motor lock

From stencil.wiki
Revision as of 21:21, 14 January 2025 by IssuePress (talk | contribs)
{{{title}}}

This tutorial[1] provides step-by-step instructions to replace a broken gear powered by the Thermal Pressure Motor. This process applies to most Riso Z-type (and beyond ) duplicators and is demonstrated here on an MZ1070. The error messages "T19-208" or similar codes such as "T19-XXX" may indicate the need for this replacement.

Overview

The gear in question is prone to wear over time. Replacement gears, such as part #612-10010, are commonly available on platforms like AliExpress or eBay. It is recommended to acquire the replacement part before beginning the procedure.

Steps

Step 1: Remove the outer cover of the Master Removal Unit (feed side)

There are 5 screws in total.

Unscrew and carefully remove the cover (might be hooked in a bit on the left side)

  1. his tutorial is adapted from an original submission by RisoFort.